Moe’s Southwest Grill scores 90 on Henry County food-safety inspection

Category:

,

• Published:

Official Georgia food-service inspection report for Moe's Southwest Grill

Moe’s Southwest Grill received a score of 90 and a grade of A during a Georgia Department of Public Health inspection conducted November 25, 2026. The score reflects conditions observed during that inspection.

Inspection details

Establishment: Moe’s Southwest Grill

Location: 1146 HWY 20/81 MCDONOUGH, GA 30253, Henry County

Inspection date: November 25, 2026

Inspection purpose: Routine

Score and grade: 90/A

Inspector: Rachel Williams

Permit number: 075-04-FSVC-003365

Inspection findings

4-2B – food-contact surfaces: cleaned & sanitized

Rule citation: 511-6-1.05(6)(n) – manual and mechanical warewashing equipment, chemical sanitization-temperature, ph, concentration, hardness (p,pf)

Official point value: 4

Corrected during inspection: No

Repeat violation: No

Inspector notes and corrective action: Observed quaternary ammonium sanitizer in 3-compartmen sink not dispensing at the proper minimum concentration. The dispensed sanitizer had very strong fumes that caused lung irritation. PIC was advised to manually add sanitizer solution. 511-6-1.05(6)(n) – Manual and Mechanical Warewashing Equipment, Chemical Sanitization-Temperature, pH, Concentration, Hardness (P,Pf) (n) Manual and Mechanical Warewashing Equipment, Chemical Sanitization – Temperature, pH, Concentration, and Hardness. A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation at contact times specified under subsection (8)(b)3 of this Rule shall meet the requirements specified in DPH Rule 511-6-1-.07(6)(g), shall be used in accordance with the Environmental Protection Agency (EPA)-registered label use instructions P, and shall be used as follows: 1. A chlorine solution shall have a minimum temperature based on the concentration and pH of the solution as listed in the following chart; P Concentration Range Minimum Temperature MG/L PH 10 or less oF (oC) PH 8 or less oF (oC) 25-49 120 (49) 120 (49) 50-99 100 (38) 75 (24) 100 55 (13) 55 (13) 2. An iodine solution shall have a minimum temperature of 68°F (20°C)P minimum concentration between 12.5 ppm and 25 ppm, P and pH of 5.0 or less or a pH no higher than the level for which the manufacturer specifies for the solution to be effective; P 3. A quaternary ammonium compound solution shall have a minimum temperature of 75ºF (24ºC), P have a concentration as specified in DPH Rule 511-6-1-.07(6)(g) and as indicated by the manufacturer’s use directions included in the labeling, P and be used only in water with 500 ppm hardness or less or in water having a hardness no greater than specified by the EPA-registered label use instructions; P 4. If another solution of a chemical specified under paragraphs 1 through 3 of this subsection is used, the permit holder shall demonstrate to the Health Authority that the solution achieves sanitization and the use of the solution shall be approved; P 5. If a chemical sanitizer other than chlorine, iodine, or a quaternary ammonium compound is used, it shall be applied in accordance with the EPA-registered label use instructions ;P and 6. If a chemical sanitizer is generated by a device located on-site at the food service establishment, it shall be used as specified in 1-5 of this subsection and shall be produced by a device that: (i) complies with law as specified in sections 2(q)(1) and 12 of the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA), P (ii) complies with 40 CFR 152.500 Requirement for Devices and 40 CFR 156.10 Labeling Requirements, P (iii) displays the EPA device manufacturing facility registration number on the device, Pf and (iv) is operated and maintained in accordance with manufacturer’s instructions. Pf. 7. On-site chemical sanitizer generating equipment with active ingredients, such as copper, must be registered as pesticides. The active ingredient may be part of the equipment or separately added.

12B – personal cleanliness

Rule citation: 511-6-1.03(5)(j) – hair restraints (c)

Official point value: 3

Corrected during inspection: No

Repeat violation: No

Inspector notes and corrective action: Observed employees with hair not properly restrained. 511-6-1.03(5)(j) – Hair Restraints (C) (i) Hair Restraints. 1. Employees preparing or handling food shall use effective and clean, disposable or easily cleanable nets or other hair restraints approved by the Health Authority, worn properly to restrain loose hair including beards and mustaches longer than one half inch. 2. This does not apply to employees such as counter staff who only serve beverages and wrapped or packaged foods, hostesses, and wait staff if they present a minimal risk of contaminating exposed food, clean utensils and linens and unwrapped single-service and single-use articles.

12C – wiping cloths: properly used and stored

Rule citation: 511-6-1.04(4)(m) – wiping cloths, use limitation (c)

Official point value: 3

Corrected during inspection: Yes

Repeat violation: No

Inspector notes and corrective action: Observed sanitizer solution stored in quaternary ammonium sanitizer solution below proper minimum concentration. PIC remade sanitizer solution. 511-6-1.04(4)(m) – Wiping Cloths, Use Limitation (C) (m) Wiping Cloths, Use Limitation. 1. Cloths in-use for wiping food spills from tableware and carry-out containers that occur as food is being served shall be: (i) Maintained dry; and (ii) Used for no other purpose. 2. Cloths in-use for wiping counters and other equipment surfaces shall be: (i) Held between uses in a chemical sanitizer solution at a concentration specified under DPH Rule 511-6-1-.05(6)(n); and (ii) Laundered daily. 3. Cloths in-use for wiping surfaces in contact with raw animal foods shall be kept separate from cloths used for other purposes. 4. Dry wiping cloths and the chemical sanitizing solutions in which wet wiping cloths are held between uses shall be free of food debris and visible soil. 5. Containers of chemical sanitizing solutions in which wet wiping cloths are held between uses shall be stored off the floor and used in a manner that prevents contamination of food, equipment, utensils, linens, single-service, or single-use articles. 6. Single-use disposable sanitizer wipes shall be used in accordance with EPA-approved manufacturer’s label use instructions.

15B – warewashing facilities: installed, maintained, used; test strips

Rule citation: 511-6-1.05(6)(p) – warewashing equipment, determining chemical sanitizer concentration (pf)

Official point value: 1

Corrected during inspection: No

Repeat violation: No

Inspector notes and corrective action: Observed expired test strips (Dec 2022 and Sep 2026) for quaternary ammonium sanitizer solution. PIC was provided test strips during the inspection to properly test sanitizer solution. 511-6-1.05(6)(p) – Warewashing Equipment, Determining Chemical Sanitizer Concentration (Pf) (p) Warewashing Equipment, Determining Chemical Sanitizer Concentration. Concentration of the sanitizing solution shall be accurately determined by using a test kit or other device. Pf.

15C – nonfood-contact surfaces clean

Rule citation: 511-6-1.05(7)(a)2,3 – equipment, food/nonfood-contact surfaces, and utensils, food-contact surfaces of cooking equipment & nonfood-contact surfaces free of accumulations (c)

Official point value: 1

Corrected during inspection: No

Repeat violation: No

Inspector notes and corrective action: Observed black mold like accumulation on caulking behind 3-compartment sink. 511-6-1.05(7)(a)2,3 – Equipment, Food/Nonfood-Contact Surfaces, and Utensils, food-contact surfaces of cooking equipment & nonfood-contact surfaces free of accumulations (C) 2. The food-contact surfaces of cooking equipment and pans shall be kept free of encrusted grease deposits and other soil accumulations. 3. Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.

17C – physical facilities installed, maintained, and clean

Rule citation: 511-6-1.07(5)(a),(b) – good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)

Official point value: 1

Corrected during inspection: No

Repeat violation: Yes

Inspector notes and corrective action: Observed baseboard tiles missing throughout the kitchen and entry way into the main kitchen in disrepair. 511-6-1.07(5)(a),(b) – Good Repair, physical facilities maintained; Cleaning, Frequency & Restrictions, cleaned often enough to keep them clean (C) (5) Maintenance and Operation. (a) Good Repair. All physical facilities shall be maintained in good repair. (b) Cleaning, Frequency and Restrictions. 1. The physical facilities shall be cleaned as often as necessary to keep them clean and by methods that prevent contamination of food products. 2. Except for cleaning that is necessary due to a spill or other accident, cleaning shall be done during periods when the least amount of food is exposed, such as after closing. 3. If present, playground equipment and associated areas shall be maintained in a clean and sanitary condition. In addition, a cleaning and sanitizing plan along with cleaning and sanitizing records for playground equipment and associated areas shall be maintained within the food service establishment for review upon request by the Health Authority. Further, such cleaning and sanitizing plan for employees to follow in the event of encountering vomitus or fecal matter shall be included and submitted at the time of permit application as specified in DPH Rule 511-6-1-.02(1)(c). Pf

17D – adequate ventilation and lighting; designated areas used

Rule citation: 511-6-1.07(3)(f) – lighting intensity, adequate in food prep, storage & service areas (c)

Official point value: 1

Corrected during inspection: No

Repeat violation: No

Inspector notes and corrective action: Observed low light intensity in walk-in cooler not allowing for food items in the back of the cooler to be clearly viewed. 511-6-1.07(3)(f) – Lighting Intensity, adequate in food prep, storage & service areas (C) (f) Lighting Intensity. The light intensity shall be: 1. At least 10 foot candles (108 lux) at a distance of 30 inches (75 cm) above the floor, in walk-in refrigeration units and dry food storage areas and in other areas and rooms during periods of cleaning; 2. At least 20 foot candles (215 lux): (i) At a surface where food is provided for consumer self-service such as buffets and salad bars or where fresh produce or packaged foods are sold or offered for consumption; (ii) Inside equipment such as reach-in and under-counter refrigerators; (iii) At a distance of 30 inches (75 cm) above the floor in areas used for handwashing, warewashing, and equipment and utensil storage, and in toilet rooms; and 3. At least 50 foot candles (540 lux) at a surface where a food service employee is working with food or working with utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor.

General inspector comments

Please provide documentation of the maintenance/repair of the 3-compartment sink dispenser unit to rachel.williams@dph.ga.gov by 12/4/26

About the report

The Georgia Department of Public Health report documents conditions observed during this inspection. The score should not be interpreted as a guarantee of conditions before or after the inspection.

Marcus Jones
News Now Georgia

Share This Story

Make a one-time donation

Thanks for your generosity!

Donate