Southern Oaks scores 84 on Franklin County food-safety inspection

Category:

,

• Published:

Official Georgia food-service inspection report for Southern Oaks

Southern Oaks received a score of 84 and a grade of B during a Georgia Department of Public Health inspection conducted November 18, 2026. The score reflects conditions observed during that inspection.

Inspection details

Establishment: Southern Oaks

Location: 30 BAKER STREET LAVONIA, GA 30553, Franklin County

Inspection date: November 18, 2026

Inspection purpose: Routine

Score and grade: 84/B

Inspector: Donya Glenn

Permit number: FSP-059-000109

Inspection findings

6-2 – proper date marking and disposition

Rule citation: 511-6-1.04(6)(g) – ready-to-eat time/temperature control for safety food, date marking (pf)

Official point value: 4

Corrected during inspection: No

Repeat violation: No

Inspector notes and corrective action: Observed in house made salad dressing (11/4) and confit (11/4) with a date that exceeds 7 days. Rule: 511-6-1.04(6)(h) – Ready-To-Eat Time/Temperature Control for Safety Food, Disposition (P) (h) Ready-to-Eat, Time/Temperature Control for Safety Food, Disposition. 1. A food that requires datemarking shall be discarded if it: (i) Exceeds 7 days, not including the time that the product is frozen; (ii) Is in a container or package that does not bear a date or day; OR (iii) Is inappropriately marked with a date or day that exceeds 7 days

9-2 – compliance with variance, specialized process and haccp plan

Rule citation: 511-6-1.02(5)(a)(b) – when a haccp plan is required (c)

Official point value: 4

Corrected during inspection: No

Repeat violation: Yes

Inspector notes and corrective action: Observed ROP of items that require a HACCP plan. The required plan has not been approved by HA. CA: Discontinue ROP of beef products until plan is submitted and approved by our office.

11C – approved thawing methods used

Rule citation: 511-6-1.04(6)(c) – thawing (c)

Official point value: 3

Corrected during inspection: No

Repeat violation: No

Inspector notes and corrective action: Observed five packets of salmon being thawed inside of the ROP packaging. PIC discarded the salmon. CA: To follow manufactures instructions on packaging to remove fish from ROP environment when thawed. 511-6-1.04(6)(c) – Thawing (C) (c) Thawing. Except as specified in paragraph 4 of this subsection, time/temperature control for safety food shall be thawed: 5. Reduced oxygen packaged fish that bears a label indicating that it is to be kept frozen until time of use shall be removed from the reduced oxygen environment

15C – nonfood-contact surfaces clean

Rule citation: 511-6-1.05(7)(d) – nonfood-contact surfaces (c)

Official point value: 1

Corrected during inspection: No

Repeat violation: Yes

Inspector notes and corrective action: Observed vent hood not clean and has excessive buildup of grease. RCA: Thoroughly clean the vent hood to prevent further accumulation. Rule:511-6-1.05(7)(d) – Nonfood-Contact Surfaces (C) (d) Nonfood-Contact Surfaces. Nonfood-contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil residues.

17C – physical facilities installed, maintained, and clean

Rule citation: 511-6-1.07(5)(a),(b) – good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)

Official point value: 1

Corrected during inspection: No

Repeat violation: No

Inspector notes and corrective action: NOTE: Observed Walk in Freezer gasket to be in bad repair. PIC to replace gasket on WIF.

17C – physical facilities installed, maintained, and clean

Rule citation: 511-6-1.07(2)(c) – floor and wall junctures, coved, & enclosed or sealed, water-flushed floors provided with drains & graded to drain (c)

Official point value: 1

Corrected during inspection: No

Repeat violation: No

Inspector notes and corrective action: Observed coving in pantry and under 3 compartments sink to be in bad repair. PIC to repair coving. Rule: 511-6-1.07(2)(c) – Floor and Wall Junctures, Coved, & Enclosed or Sealed, water-flushed floors provided with drains & graded to drain (C) (c) Floor and Wall Junctures, Coved, and Enclosed or Sealed. 1. In food service establishments in which cleaning methods other than water flushing are used for cleaning floors, the floor and wall junctures shall be coved and closed to no larger than one thirty-second inch (1 mm). 2. The floors in food service establishments in which water flush cleaning methods are used shall be provided with drains and be graded to drain, and the floor and wall junctures shall be coved and sealed.

General inspector comments

Pest Control Serviced Week of 11/9/2026 Sanitizer Bucket – @400ppm Dish Machine Chlorine – @ Joint Inspection w/ Allison Nelson

About the report

The Georgia Department of Public Health report documents conditions observed during this inspection. The score should not be interpreted as a guarantee of conditions before or after the inspection.

Victoria Sterling
News Now Georgia

Share This Story

Make a one-time donation

Thanks for your generosity!

Donate